v1.3.5 FINAL bug reports and comments

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
sirhc
Employee
Employee
 
Posts: 7415
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

v1.3.5 FINAL bug reports and comments

Tue Oct 27, 2015 8:40 pm

Please post comments and reports bugs with v1.3.5 FINAL in this thread

v1.3.5 wrote:FIXES
- Fixed flow control on dual SFP ports
- Fixed PoE power being turned off when port is disabled
- Fixed problem with MAC table not being displayed
- Fixed selecting 24V when bulk editing PoE settings
- Fixed bug parsing times in timed shutdown periods for PoE on DC models
- Fixed login problem when changing credentials name without also changing password
- Fixed DHCP fails it falls back to a static address but continues to try to get a DHCP address
- Fixed setting SNMP community string in CLI
- Fixed problem with changes to Switch Name not taking effect immediately

ENHANCEMENTS
- Added autonegotiation to dual SFP ports
- Added error condition notifications to the UI
- Added meters to UI
- Added sysDescr to SNMP with model number
- Added missing indexes to SNMP (fan, voltage, poe status and temp)
- Added SMTP Local Hostname option
- Added root bridge ID and port role to STP tab
- Added PoE Smart check for suspected 24V devices when selecting 24VH POE
- Added option to use web interface on HTTP as well as HTTPS

KNOWN ISSUES
- Ubiquiti Discovery Protocol is still flaky
- IPERF is still a work in progress
- WS-6-MINI and WS-8-250-AC and WS-8-250-DC always see a reboot as cold which you may have your first POE Port Shut OFF after reboot.
We are working on this ISSUE
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
lligetfa
Associate
Associate
 
Posts: 1191
Joined: Sun Aug 03, 2014 12:12 pm
Location: Fort Frances Ont. Canada
Has thanked: 307 times
Been thanked: 381 times

Re: v1.3.5 FINAL bug reports and comments

Tue Oct 27, 2015 9:51 pm

Upgraded WS24 and WS6 from 1.2.4 with no issues.

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: v1.3.5 FINAL bug reports and comments

Tue Oct 27, 2015 10:22 pm

Les, thanks.

Do you like the new GUI Meter's?

Dave

User avatar
adairw
Associate
Associate
 
Posts: 465
Joined: Wed Nov 05, 2014 11:47 pm
Location: Amarillo, TX
Has thanked: 98 times
Been thanked: 132 times

Re: v1.3.5 FINAL bug reports and comments

Tue Oct 27, 2015 11:21 pm

Just loaded it on my WS-8 at home. I do like the GUI meters. very easy to see at a glance what's going on. Nice work guys!

User avatar
lligetfa
Associate
Associate
 
Posts: 1191
Joined: Sun Aug 03, 2014 12:12 pm
Location: Fort Frances Ont. Canada
Has thanked: 307 times
Been thanked: 381 times

Re: v1.3.5 FINAL bug reports and comments

Wed Oct 28, 2015 12:57 am

Dave wrote:Do you like the new GUI Meter's?
Yes, I do.

I am getting nagged now in the log on the MINI. It is on the end of a buried 300 foot CAT5e run so voltage drop is to be expected.

I think the "48V is out of range" would normally be a one time alert but the i2c error and subsequent retry brings it back up.

From the MINI
Oct 27 20:04:03 switch[1343]: 48V is out of range (44.5V)
Oct 27 20:30:43 switch[1343]: i2c error: arbitration lost stop
Oct 27 20:30:54 switch[1343]: retrying i2c
Oct 27 20:30:54 switch[1343]: 48V is out of range (44.2V)
Oct 27 20:36:06 switch[1343]: i2c error: arbitration lost stop
Oct 27 20:36:17 switch[1343]: retrying i2c
Oct 27 20:36:17 switch[1343]: 48V is out of range (44.5V)
Oct 27 21:07:17 switch[1343]: i2c error: arbitration lost stop
Oct 27 21:07:28 switch[1343]: retrying i2c
Oct 27 21:07:28 switch[1343]: 48V is out of range (44.2V)


On the WS24, I get the following. Not using PoE on ports 13-24.
Oct 27 20:26:04 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)
Oct 27 21:00:14 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)
Oct 27 21:04:46 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)
Oct 27 21:39:10 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)
Oct 27 21:46:49 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)
Oct 27 22:06:10 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)
Oct 27 22:07:48 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)
Oct 27 22:25:18 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)
Oct 27 22:27:05 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)
Oct 27 22:58:11 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)
Oct 27 22:59:49 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)
Oct 27 23:05:16 switch[1381]: 24V (Ports 13-24) is out of range (23.7V)


The label on what is the SMTP Test button has undefined instead.

User avatar
adaptit
Member
 
Posts: 3
Joined: Wed Oct 07, 2015 9:57 am
Location: Herts, United Kingdom
Has thanked: 1 time
Been thanked: 0 time

Re: v1.3.5 FINAL bug reports and comments

Wed Oct 28, 2015 3:40 am

Be careful guys. I just upgraded 5 of the 6 port mini switches with no problem...like the new features although the log is highlighting on two of my switches that board voltage is out of range (23.7v) however I have 48.7 volts on the board, so not sure how the 24 volt board can report as low?

The reason I said be careful is because I just flashed ws-12-250a and it never came back. The entire site is now down and I am about to drive 40 miles to find out what happened. The switch had the previous release of firmware and had upgraded fine last time.

Regards
Derek

User avatar
quantumx
Member
 
Posts: 24
Joined: Wed Dec 03, 2014 1:46 pm
Location: Ontario, CANADA
Has thanked: 4 times
Been thanked: 3 times

Re: v1.3.5 FINAL bug reports and comments

Wed Oct 28, 2015 5:11 am

I ran into 1 WS-12-250-AC RevD that now reports board Power under status as:

Board 48V 13.5V
Board 24V 6.7V
Board 3V 0.3V

This seems like a reporting problem, as the switch operates normally. Any suggestions?

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: v1.3.5 FINAL bug reports and comments

Wed Oct 28, 2015 8:14 am

Sorry for the issues guys, we actually did a lot of testing..errr...we will focus on reported issues today & send out a fix ASAP...dave

User avatar
WirelessRudy
Member
 
Posts: 58
Joined: Tue Aug 04, 2015 7:44 pm
Location: Castalla, Spain
Has thanked: 3 times
Been thanked: 2 times

Re: v1.3.5 FINAL bug reports and comments

Wed Oct 28, 2015 8:31 am

Updated 1x 6 port mini, one WS-12-250-DC and 1 x WS-8-250-AC.
All went fine.
Only the mini reported in the log that the "48V is out of range (46,2V)"

The voltage is supplied by an 220=>48 Ubiquity fiber adapter. The power is supplied over about 50-55 meters of ftp cable so a drop in voltage is to be expected. (Main reason for using this Switch! Still plenty of power available to serve 4 Mikrotiks over such long wire).
But why the log message? Is 1,8V below the nominal voltage 'out of range'?

I'm going to play with the vlans now, to see if we finally can get Mikrotik vlans to pass.....

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: v1.3.5 FINAL bug reports and comments

Wed Oct 28, 2015 8:45 am

Only the mini reported in the log that the "48V is out of range (46,2V)"

The voltage is supplied by an 220=>48 Ubiquity fiber adapter. The power is supplied over about 50-55 meters of ftp cable so a drop in voltage is to be expected. (Main reason for using this Switch! Still plenty of power available to serve 4 Mikrotiks over such long wire).
But why the log message? Is 1,8V below the nominal voltage 'out of range'?


simple software fix, forgot to give a wider input voltage range check for 6 port mini due to cable voltage drop..will fix in next release soon...interested also to see if your VLAN issue is resolved...

Next
Return to Hardware and software issues