Canopy 430AP

User avatar
tcknudson
Member
 
Posts: 61
Joined: Fri Oct 30, 2015 6:43 am
Location: Henderson, NV
Has thanked: 4 times
Been thanked: 22 times

Canopy 430AP

Tue Nov 10, 2015 12:40 pm

I would assume this one is not even an option with the odd wiring?

User avatar
mike99
Associate
Associate
 
Posts: 837
Joined: Tue Nov 25, 2014 10:53 am
Location: Quebec, Canada
Has thanked: 95 times
Been thanked: 245 times

Re: Canopy 430AP

Tue Nov 10, 2015 2:57 pm

Cambium pinout normally work on standard PoE by reversing blue and brown pair. I've tryed it with ePMP but not with 430.

User avatar
mgthump
Member
 
Posts: 23
Joined: Fri Jun 19, 2015 10:31 pm
Location: Pacific, MO
Has thanked: 0 time
Been thanked: 2 times

Re: Canopy 430AP

Thu Nov 19, 2015 2:20 am

no, the PMP 320, and the PMP 430 have very unique wiring, they won't carry on anything but that POE supply or the CMM4.

if you get into the user manual, or check the power brick it shows the power layout and they apply power in the data pins, and its mixed up too.

User avatar
tcknudson
Member
 
Posts: 61
Joined: Fri Oct 30, 2015 6:43 am
Location: Henderson, NV
Has thanked: 4 times
Been thanked: 22 times

Re: Canopy 430AP

Thu Nov 19, 2015 6:58 pm

1 Data A
2 Data A
3 Data B
4 DC -
5 DC +
6 Data b
7 DC -
8 DC +
I swapped blue with brown on far end of cat5 and it powers fine from netonix in 48v mode.

crossing pin 4 to 8 on far side only
Attachments
430ap on netonix.JPG
netonix with custom wiring
Last edited by tcknudson on Wed Jan 20, 2016 5:17 pm, edited 1 time in total.

User avatar
sirhc
Employee
Employee
 
Posts: 7421
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: Canopy 430AP

Thu Nov 19, 2015 7:14 pm

tcknudson wrote:1 Data A
2 Data A
3 Data B
4 DC -
5 DC +
6 Data b
7 DC -
8 DC +
I swapped blue with brown on far end of cat5 and it powers fine from netonix in 48v mode.

crossing pin 4 to 8 on far side only


I do not see how this does not fry your port?

I can see swapping both pairs pins 4,5 with pins 7,8 on one side but you are creating a cross short between pairs this way. - BAD

Just be warned that cross shorts are not covered under warranty and this type of damage is easy to spot during repair. - GOOD LUCK
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
tcknudson
Member
 
Posts: 61
Joined: Fri Oct 30, 2015 6:43 am
Location: Henderson, NV
Has thanked: 4 times
Been thanked: 22 times

Re: Canopy 430AP

Thu Nov 19, 2015 7:21 pm

no, this is the only radio that is powered this way, and it does work fine like this,
Its 5,8(+) and 4,7(-)

POE.png

note.png

User avatar
tcknudson
Member
 
Posts: 61
Joined: Fri Oct 30, 2015 6:43 am
Location: Henderson, NV
Has thanked: 4 times
Been thanked: 22 times

Re: Canopy 430AP

Tue Nov 24, 2015 7:06 pm

the ws-6 switch (when powered by POE) will not boot up a Canopy 430AP with the configuration we suggested, keeps rebooting, I think it is too much startup amperage, works fine on dc 250 and ac 250 version,

I think it worked with barrel connection even on the ws-6 but I cannot replicate test as I have to locate another barrel connector,

User avatar
sirhc
Employee
Employee
 
Posts: 7421
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: Canopy 430AP

Tue Nov 24, 2015 7:08 pm

tcknudson wrote:the ws-6 switch (when powered by POE) will not boot up a Canopy 430AP with the configuration we suggested, keeps rebooting, I think it is too much startup amperage, works fine on dc 250 and ac 250 version,

I think it worked with barrel connection even on the ws-6 but I cannot replicate test as I have to locate another barrel connector,


What were you using to power the WS-6-MINI, a AF24 POE brick or another WISP Switch?

And if a WISP switch what is the power rating on the WISP Switch 48VH port as older Rev boards only support 1.2A on 48VH but newer Rev boards support 1.5A
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
tcknudson
Member
 
Posts: 61
Joined: Fri Oct 30, 2015 6:43 am
Location: Henderson, NV
Has thanked: 4 times
Been thanked: 22 times

Re: Canopy 430AP

Tue Nov 24, 2015 8:17 pm

I tried powering ws-6 mini via a 48VH port on a dc Netonix and on 48VH AC Netonix, as well as a 1.2 amp Ubiquity power supply for the airfiber 24.
Also the radio shows it requires 915 ma which is over the .75 amp in the switch, but I measured it when running on the bigger two switches, and it never went over 15 watts.
Might be a startup amp requirement issue?