Backup / Restore bug - 1.3.8

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
alidamji
Member
 
Posts: 2
Joined: Sat Apr 11, 2015 2:07 pm
Location: Dar es Salaam, Africa
Has thanked: 3 times
Been thanked: 0 time

Backup / Restore bug - 1.3.8

Mon Nov 30, 2015 6:13 am

Backing up a WS-12-250-DC and restoring the config on a WS-12-250-AC makes the WS-12-250-AC to become a WS-12-250-DC model and shows the "Power" tab as well.

User avatar
Dave
Employee
Employee
 
Posts: 726
Joined: Tue Apr 08, 2014 6:28 pm
Has thanked: 1 time
Been thanked: 158 times

Re: Backup / Restore bug - 1.3.8

Mon Nov 30, 2015 9:11 am

alidamji

You got me on this one, never thought about trying to back up a configuration to a different model.

Thanks for reporting this. We will get this fixed.

Dave

User avatar
Eric Stern
Employee
Employee
 
Posts: 532
Joined: Wed Apr 09, 2014 9:41 pm
Location: Toronto, Ontario
Has thanked: 0 time
Been thanked: 130 times

Re: Backup / Restore bug - 1.3.8

Mon Nov 30, 2015 11:18 am

This isn't possible as the model is not stored in the config backup.

My best guess is that when you restored to the WS-12-250-AC the WS-12-250-DC was still running on the network and then they both had the same IP address.
When two devices have the same IP you will randomly get one of them and you ended up actually talking to the WS-12-250-DC.