No flow control indication with Mimosa B5c's

DOWNLOAD THE LATEST FIRMWARE HERE
User avatar
wtm
Experienced Member
 
Posts: 262
Joined: Sun Jan 11, 2015 12:17 am
Location: Arizona
Has thanked: 41 times
Been thanked: 36 times

No flow control indication with Mimosa B5c's

Tue Dec 15, 2015 1:41 am

Just upgraded our switches to 1.3.8 and noticed that none of my Mimosa B5c's show as having "Flow control" running on them on the switch ports.
They do connect as 1 gig, and are in "Auto" negotiation.

I know that we have both the switch and the Mimosa radios with Flow control selected as ON !
The UBNT units do show, and so does the Mikrotik routers ?

Glitch ?

User avatar
sirhc
Employee
Employee
 
Posts: 7421
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: No flow control indication with Mimosa B5c's

Tue Dec 15, 2015 9:26 am

Please do a search for an answer before you post a question as the forums will get clogged up fast with the same questions and answers.

I answered this already here: viewtopic.php?f=17&t=1220&p=9539&hilit=MIMOSA#p9539

All I did was search for "MIMOSA"
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
wtm
Experienced Member
 
Posts: 262
Joined: Sun Jan 11, 2015 12:17 am
Location: Arizona
Has thanked: 41 times
Been thanked: 36 times

Re: No flow control indication with Mimosa B5c's

Tue Dec 15, 2015 2:00 pm

Sorry, thought I posted on that, but should have done a search for it!

I will have to contact Mimosa then, as they have a FC "ON and OFF" selection for the port. What you are saying is that it does NOT do anything?

User avatar
sirhc
Employee
Employee
 
Posts: 7421
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1609 times
Been thanked: 1326 times

Re: No flow control indication with Mimosa B5c's

Tue Dec 15, 2015 2:32 pm

wtm wrote:Sorry, thought I posted on that, but should have done a search for it!

I will have to contact Mimosa then, as they have a FC "ON and OFF" selection for the port. What you are saying is that it does NOT do anything?


That is correct, our switch will report if Flow Control has negotiated and is active. Since it appears to work correctly (our reporting) with other devices I would tend to push the ball into MIMOSA'a court on this one.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

Return to Hardware and software issues

Who is online

Users browsing this forum: Google [Bot] and 7 guests