Voltage out of Range?

Tue Dec 15, 2015 2:03 pm

Hi,

I have just installed a new WS-12-250DC switch running on a 24v DC source, upgraded to Firmware 1.3.8. Everything appears fine, however in the log I am getting repeated messages every 5-10 secs.

'Switch [771] Power Supply Output Voltage is out of range (50.4v)'

On the system status page everything is in the green.

Should I be concerned or is this a a small bug in an otherwise great device?

Thanks in Advance.

Chris

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Voltage out of Range?

Tue Dec 15, 2015 4:04 pm

Mainland wrote:Hi,

I have just installed a new WS-12-250DC switch running on a 24v DC source, upgraded to Firmware 1.3.8. Everything appears fine, however in the log I am getting repeated messages every 5-10 secs.

'Switch [771] Power Supply Output Voltage is out of range (50.4v)'

On the system status page everything is in the green.

Should I be concerned or is this a a small bug in an otherwise great device?

Thanks in Advance.

Chris

That is a bug where we were to picky about allowed ranges and has been changed in the v1.3.9rcX versions
I would review Release notes for v1.3.9rcX and try v1.3.9rcX, I am about to post up v1.3.9rc8
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
Mainland
Member
 
Posts: 6
Joined: Mon Nov 16, 2015 11:29 am
Location: Kentville, NS - Canada
Has thanked: 2 times
Been thanked: 1 time

Re: Voltage out of Range?

Wed Dec 16, 2015 1:17 am

That worked. Thanks 1.3.9RC8 working well

User avatar
Mainland
Member
 
Posts: 6
Joined: Mon Nov 16, 2015 11:29 am
Location: Kentville, NS - Canada
Has thanked: 2 times
Been thanked: 1 time

Re: Voltage out of Range?

Wed Dec 16, 2015 5:59 pm

sirhc wrote:
Mainland wrote:Hi,

I have just installed a new WS-12-250DC switch running on a 24v DC source, upgraded to Firmware 1.3.8. Everything appears fine, however in the log I am getting repeated messages every 5-10 secs.

'Switch [771] Power Supply Output Voltage is out of range (50.4v)'

On the system status page everything is in the green.

Should I be concerned or is this a a small bug in an otherwise great device?

Thanks in Advance.

Chris

That is a bug where we were to picky about allowed ranges and has been changed in the v1.3.9rcX versions
I would review Release notes for v1.3.9rcX and try v1.3.9rcX, I am about to post up v1.3.9rc8


Hi,

Looks like I many have spoken too soon, the message was gone for a couple of hours then started creeping back every hour or so, now it is continuous:


Dec 16 17:55:14 switch[1367]: !Power Supply Output Voltage is out of range (50.4V)
Dec 16 17:55:24 switch[1367]: !Power Supply Output Voltage is out of range (50.4V)
Dec 16 17:55:27 switch[1367]: !Power Supply Output Voltage is out of range (50.4V)
Dec 16 17:55:34 switch[1367]: !Power Supply Output Voltage is out of range (50.4V)
Dec 16 17:55:38 switch[1367]: !Power Supply Output Voltage is out of range (50.4V)
Dec 16 17:55:41 switch[1367]: !Power Supply Output Voltage is out of range (50.4V)
Dec 16 17:55:45 switch[1367]: !Power Supply Output Voltage is out of range (50.4V)

Apart from that everything else looks good.

Regards.

Chris

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Voltage out of Range?

Wed Dec 16, 2015 6:05 pm

Thanks Mainland, we are reviewing this. Obviously there is nothing wrong with the hardware our valid ranges are simply too narrow.

Could you please post up the Main Status Tab and Device/Configuration Tab as I would like to gauge the load on the switch.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
Mainland
Member
 
Posts: 6
Joined: Mon Nov 16, 2015 11:29 am
Location: Kentville, NS - Canada
Has thanked: 2 times
Been thanked: 1 time

Re: Voltage out of Range?

Wed Dec 16, 2015 9:55 pm

sirhc wrote:Thanks Mainland, we are reviewing this. Obviously there is nothing wrong with the hardware our valid ranges are simply too narrow.

Could you please post up the Main Status Tab and Device/Configuration Tab as I would like to gauge the load on the switch.


No Problem:
Image
Image
Image

Hope that helps, it is very lightly loaded.

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Voltage out of Range?

Wed Dec 16, 2015 10:04 pm

Please don't forget the Device/Configuration Tab
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
Mainland
Member
 
Posts: 6
Joined: Mon Nov 16, 2015 11:29 am
Location: Kentville, NS - Canada
Has thanked: 2 times
Been thanked: 1 time

Re: Voltage out of Range?

Wed Dec 16, 2015 11:09 pm

sirhc wrote:Please don't forget the Device/Configuration Tab


Sorry here you go. Under Device / Configuration everything is default, except my SMTP credentials and NTP server

Here is device Status.

Image

User avatar
sirhc
Employee
Employee
 
Posts: 7416
Joined: Tue Apr 08, 2014 3:48 pm
Location: Lancaster, PA
Has thanked: 1608 times
Been thanked: 1325 times

Re: Voltage out of Range?

Thu Dec 17, 2015 12:41 am

Thanks, we will increase the range in the next release.

I take it that the alert happens sporadically?


You do know that the prefered POE option for airFIBER X radios like on port 2 should be 24VH.

24V is OK up to about 200' of cable but if you have 24VH at your disposal you should use it.
Support is handled on the Forums not in Emails and PMs.
Before you ask a question use the Search function to see it has been answered before.
To do an Advanced Search click the magnifying glass in the Search Box.
To upload pictures click the Upload attachment link below the BLUE SUBMIT BUTTON.

User avatar
Mainland
Member
 
Posts: 6
Joined: Mon Nov 16, 2015 11:29 am
Location: Kentville, NS - Canada
Has thanked: 2 times
Been thanked: 1 time

Re: Voltage out of Range?

Thu Dec 17, 2015 12:50 am

sirhc wrote:Thanks, we will increase the range in the next release.

I take it that the alert happens sporadically?


You do know that the prefered POE option for airFIBER X radios like on port 2 should be 24VH.

24V is OK up to about 200' of cable but if you have 24VH at your disposal you should use it.


Yes it is a sporadic message, now it's around 10 seconds, I was aware that 24VH was the 'normal' way of powering an AF-X but did not realize it would give any benefit on short runs (this is about 50ft) however if it could provide any advantages I will change it.

Anyway thanks for all your help and wish you luck with a great product. it's goodbye to all the tough switches in our network, Hello Netonix, having a native DC option was a killer move.