cbl wrote:Put on rc8 on a new WS-12-250-DC. I changed the MTU on each port to 9600 from the default MTU size, and upon submit I get a "Error applying configuration!" popup. Clicking OK, I get a "Applying configuration... " countdown like normal. Upon refresh I see the MTUs were properly set to 9600. Not sure if this is new in rc8 or not.
I was able to duplicate this. It happens if you change the MTU on the port that the MAC is connected to. When the MTU is changed the link is dropped briefly and that causes Safari to lose the connection and display the error dialog. As you noticed the configured is saved and applied correctly.
This is a bug in Safari (or at least an unwanted feature), and I can't think of a way to work around it. But I think I'm not going to worry about it since:
- it only happens when using Safari on OSX (Firefox and Chrome on OSX work fine, all browsers on Windows work fine)
- it only happens if the computer is directly connected to the switch
- it only happens if changing the MTU or link speed on the port the computer is connected to
Thats a very specific configuration that won't happen very often. It'll basically only ever happen on the test bench, since if you are remotely managing the switch you won't be directly connected to it.